-40%
Commscope O-004-DA-8W-F04NS 4 CT SM Jacketed Armored Fiber Cable-5046' Reel
$ 607.19
- Description
- Size Guide
Description
CommscopeO-004-DA-8W-F04NS 4 CT Single Mode, Single Jacket, Single Armor, Arid-Core Fiber Optic Drop Cable-5018' Reel
This will ship LTL. Shipping cost will be quoted based on ship to location, commercial or residential address and any other special services needed such as lift gate, advance notification, delivery appointment.
General Specifications
Cable Type
Central loose tube
Construction Type
Armored
Subunit Type
Gel-filled
Construction Materials
Fiber Type Solution
TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1 | OS2)
Jacket Material
PE
Total Fiber Count
4
Armor Type
Corrugated steel
Fiber Type
TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1 | OS2)
Fiber Type, quantity
4
Fibers per Subunit, quantity
4
Jacket Color
Black
Jacket UV Resistance
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
3.00 mm | 0.12 in
Cable Weight
69.0 kg/km | 46.0 lb/kft
Diameter Over Jacket
8.00 mm | 0.31 in
Subunit, quantity
1
Physical Specifications
Minimum Bend Radius, loaded
12.0 cm | 4.7 in
Minimum Bend Radius, unloaded
8.0 cm | 3.1 in
Tensile Load, long term, maximum
400 N | 90 lbf
Tensile Load, short term, maximum
1334 N | 300 lbf
Vertical Rise, maximum
595.0 m | 1952.1 ft
Environmental Specifications
Environmental Space
Aerial, lashed | Buried
Installation Temperature
-30 °C to +70 °C (-22 °F to +158 °F)
Operating Temperature
-40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature
-40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression
10 N/mm | 57 lb/in
Compression Test Method
FOTP-41 | IEC 60794-1-2, Section 7
Flex
35 cycles
Flex Test Method
FOTP-104 | IEC 60794-1-2, Section 10
Impact
2.17 ft lb | 2.94 N-m
Impact Test Method
FOTP-25 | IEC 60794-1-2, Section 8
Strain
See long and short term tensile loads
Strain Test Method
FOTP-33 | IEC 60794-1-2, Section 5
Twist
10 cycles
Twist Test Method
FOTP-85 | IEC 60794-1-2, Section 11
Water Penentration
24 h
Water Penentration Test Method
FOTP-82 | IEC 60794-1-2, Section 24
Environmental Test Specifications
Cable Freeze
-2 °C | 28 °F
Cable Freeze Test Method
FOTP-98
Drip
70 °C | 158 °F
Drip Test Method
FOTP-81 | IEC 60794-1-2, Section 17
Heat Age
-40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method
Not applicable
Low High Bend
-30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method
FOTP-28 | IEC 60794-1-2, Section 28
Temperature Cycle
-40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method
FOTP-3 | IEC 60794-1-2, Section 22
Qualification Specifications
Cable Qualification Standards
ANSI/ICEA S-110-717 | EN 187105 | Telcordia GR-20
Regulatory Compliance/Certifications
Agency
Classification
RoHS 2011/65/EU
Compliant
ISO 9001:2008
Designed, manufactured and/or distributed under this quality management system